Magnetic Particle | - Semi-portable
- Sensitive to small indications
- Defects surface and near surface defects
- Sensitive to inclusions as well as cracks
- Moderate skill is required
| - Only suitable for ferro magnetic material
- Part must be physically and visually accessible to perform test
- Removal of most surface coatings and sealant required
- Inspection is semi-direction requiring a general orientation of field to defect
- Not usable in area where strong magnetic field may damage instruments
- Part must be demagnetized after inspection
|
Useful table, could be good to keep on hand for those less experienced with magnetic particle inspection.
ReplyDelete- Zul TesTex NDT Ltd
The inspection went well and Larry found a carbon monoxide hazard that threatened the seller living in the condo. After this find, Larry told the seller about the issue and how to fix it. All in all, Larry was through and provided good customer service. vaughan home inspection